Product Advantages
• The product can be mixed with a filling agent up to the rate of 1:1
• Has low viscosity; easily penetrates into hairline cracks on the surface.
• Provides a better and space free adhesion of the epoxy floor covering to the surface.
• Has high penetration ability.
• Has high adhesion strength.
• High resistance to mechanical influences. • Free from solvents, and environmentally friendly.
Usage Areas
- MegaFilm A502 is mainly used as primer on cement-based screed and concrete surfaces prior to floor covering with epoxy. Application in indoor areas on horizontal surfaces.
Technical Informations
- PerformanceAdhesion Strength ≥ 2,0 (1,5) N/mm2 EN 1504 – 2 / EN 1542
Abrasion Resistance < 3000 mg EN 1504 – 2 / EN ISO 5470-1
Carbon Dioxide Permeability sd ≥ 50 m EN 1504 – 2 / EN 1062 – 6
Water Vapor Permeability Class III EN 1504 – 2 / EN ISO 7783 – 1
Capillary Water Absorption and Water
Permeability w < 0,1 kg/m2.h0,5 EN 1504 – 2 / EN 1062 – 3
Chemical Resistance Class II EN 1504 – 2 / EN 13529These values have been obtained by tests done under laboratory circumstances with 23 ± 2°C and 50% ± 5 relative humidity. The values given in the table may vary according to different surface and ambient conditions.
Application LimitsPot life ~50 minutes
Duration for proceeding to second layer MegaFilm A502 application Minimum 12 hours
Duration until opening to pedestrian traffic 24 hours
Waiting time until opening to light traffic load 4 days
Complete drying time 7 daysThese results are gathered under laboratory conditions with 23 ± 2°C temperature and %50 ± 5 relative humidity. The values given in the table may vary according to different surface and ambient conditions.
Technicial Specificationsa. Chemical Structure: Epoxy resinous based
b. Amount of non-volatile solids: 100% by volume and weight
c. Density (Component A): ~ 1,10 kg/l
d. Density (Component B): ~ 1,00 kg/l
e. Density (Mixture): ~ 1,05 kg/l
f. Color: TransparentMixing RatioComponent A (10 kg) and Component B (5 kg) must be mixed thoroughly. (2:1 ratio by weight)
ConsumptionPrimer (less porous) 1 x MegaFilm A502 0,30 – 0,50 kg/m2
Primer (very porous) 2 x MegaFilm A502 0.7 – 1,0 kg/m2
For consumptions to different application with MegaFilm A502, please call our Technical Support Hotline. (TEL: 444 4 595)PackagingMegaFilm A502 is offered as set with Component A with net 10 kg and Component B with 5 kg in tin buckets.
Reference Standardsa. Approvals/Standards
• EN 1504-2
Ministry of Public Works Pos. No.
• Ministry of Public Works Pos. No.: 10.300.2152Certificates Of Quality
• CE
Application Procedure
- Application Surfaces
Interior Floors;
Cement based screed
ConcreteInterior Walls;
Cement based screed
ConcreteSurface Preparation :
• The surface should be dry, clean, firm and dust free; grease, dirt and any materials that could prevent adhesion should be removed from the surface; materials such as mortar or cement residues should be scraped off,
• Before application of the primer on the surface, an open porous structure should be formed in the upper layer of the application surface by using surface abrasive equipment (such as Shot Blast, Rototiger etc.). The resulting dust should be cleaned with an industrial vacuum cleaner.
• The pressure strength of the abraded concrete surface should be minimum 25 N/mm2 and the tensile strength should be minimum 1.5 N/mm2.
• Before application, make sure that the surface moisture, relative humidity and dew point requirements are met. Otherwise, the desired criteria cannot be achieved as a result of the carbonation reaction that will take place on the surface.
• Moisture content of the surface should be maximum 4%.
• In case the surface humidity is higher than 4%, please call our technical support line for information.
• Relative humidity should be maximum 80%.
• In order to prevent condensation before and after the application, the dew point should be above +3oC.
• New concrete constructions should be left to dry a minimum of 28 days.
• In the surfaces landed on soil, waterproofing application must be done in accordance with the related local Waterproofing Regulations.
• Surface defects with more than 1 cm in depth should be repaired 6-8 hours in advance with MegaTamir Epo T501 and/or with MegaTamir EpoGrout T502.Application Methods :
• The prepared mixture MegaFilm A502 should be poured onto the surface and applied by a roller or trowel until a seamless layer is formed.
• It should be considered that the pot life and workable period of epoxy based products may decrease and increase depending on the ambient humidity and temperature.
• The second layer of MegaFilm A502 should be applied according to the porosity of the surface.
• If MegaZemin Z501 application shall be done after the primer application, it can be blunted with quartz or silica sand in dimensions of 0.5 – 0.7 mm.Application Suggestions :
• All materials that will be used in order to reduce the negative effects of thermal differentiation should be brought to the application area 24 hours in advance.
• Before proceeding to the final coat application, it should be ensured that the primer application is suitable for the pedestrian traffic.
• Ambient temperature and humidity should be kept under control during opening for pedestrian traffic.
• Mixing should not absolutely be done manually.
• Smoothness must be ensured to prevent water accumulation on the application surface.
• The product should be used within the pot life after mixing. Do not use products, of which the pot life has expired during application.
• Do not apply on unstable surfaces. Stability and carrying capacity of old surfaces must be checked before application.
• Protect the application surface before, during and after application against air streams; also it should be protected against water contact and condensation for 24 hours.
• Do not apply on surfaces where risk of frost hazard within the next 24 hours exists, on already frozen surfaces or those that are about to melt.
• Care should be taken to ensure, that the product is not exposed to direct sunlight during hot weathers.
• Do not apply on extremely windy and hot surfaces that are exposed to direct sunlight. If there is a necessity for application in these environments, the environment as well as the surface should be made ready for application before starting.
• For different surface applications please contact our Technical Support Hotline. (TEL: 444 4 595)Surface and Ambient Temperature
The surface and ambient temperature should be between +10°C and +30°C. When necessary, the ambient should be heated with electric heaters. It is not recommended to use heaters with combustion system as it may contaminate the surface.