Product Advantages
• 600 % elastic.
• Poses crack bridging capability.
• UV resistant
• Water vapor permeability.
• Fit for use as top coating material on roofs and terraces, which are to be left uncoated and cannot be wandered.
• Paintable after application.
• Highly adhesive.
• Ensures seamless waterproofing for application surfaces.
• A ready to use product, which is applied easily and rapidly.
• Free from solvents, and environmentally friendly.
Usage Areas
- MegaIzo Lastik 6 is used as a waterproofing material for all structures, especially for flat and inclined terrace roofs, which are intended not to be coated with another coating material, and for the waterproofing of the exterior facades of buildings.<0} {0>İç mekan, dış mekan yatay ve düşey yüzeylerde kullanılır.<}93{>It is suitable
Technical Informations
- Reference Standardsa. Certifications / Standards
• TSE
• CE
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.509
Application Procedure
- Application Surfaces
Indoors and Outdoors Walls;
Cement based trowel coating
Concrete
Indoors and Outdoors Floors;
Cement based plaster
ConcreteSurface Preparation :
Application surfaces should be sound, clean, dust free, and free from molding oils and other foreign substances. Such materials as mortar and cement residues should be peeled off.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir I or MegaTamir K 6-8 hours in advance. In the cases, where structural repair mortar should be used; MegaTamir I Yapısal or MegaTamir K Yapısal should be preferred.
For purposes of ensuring that the adhesion strength is improved and the surface absorption is balanced in the aftermath of surface cleaning, the product itself, as surface preparatory primer, is used by diluting with water at the rate of 1:1 and let dry for 3-4 hours prior to the application of Megaİzo Lastik 6.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.Application Methods :
Megaİzo Lastik 6 product, for which the mixture has been prepared, must be applied on the surface in at least two layers with dry film thickness of 1 mm. The application of the second layer and the layers after that must be made after the first layer is fully dry and in perpendicular direction to the previous application.
MegaTamir I and MegaTamir K should be applied to such inadequately waterproof spots as edge and corner joint spots in order to ensure the maintenance of insulation.
Edge and corner joints should be beveled with MegaIzo Bant repair mortars in the cases where waterproofing tape is not used.
In the cases, where net reinforcement is necessary; the net shall be laid on the primary coat before it dries.
The top coat should be applied with a trowel in order to obtain a smooth surface.Application Recommendations :
The product should not be applied to the surfaces exposed to pressure and non pressure water.
The product package should be kept closed during the rest breaks in application in order to prevent the product from freezing.
Due care must be taken to ensure that the insulation material is not damaged by mechanical impacts in the cases of coating over the insulation.
The product should not be applied against negative water pressure.
The application surface should be smoothed and inclined adequately to prevent water accumulation.
The product should, once mixed to homogenous consistency, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application.
Megaİzo Lastik 6 is a ready to use product. Any foreign material should not be added into the product during the application.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to application.
The surface should be protected from air currents during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +95°F whilst at application.
- Application Surfaces
- Reference Standardsa. Certifications / Standards