Product Advantages
• Yields effective results in structural repair applications thanks to high compressions strength.
• Fit for use for the structural repair of any reinforced concrete construction elements.
• Poses very high bonding capability.
• Enables a lasting and smooth surface following the application.
• Does not contain sulfate and chloride ions.
• Resistant to water and frost.
• Prepared and applied easily.
Usage Areas
- MegaTamir Grout T105 can be used for steel and prefabricated structures, for the foundations of machines and cranes, foundation sockets, curtain walls, column headings, and for the assemblage to the foundation of steel columns. It is also used for the filling of any gaps, holes and pores for the purpose of the assemblage of railway bearings, precast structural columns, concrete anchorages, structural bearing plates, gas and steam turbines, power generators, compressors, press machines and lathe workbenches and drilling machines. It is suitable for use on horizontal surfaces in indoors and outdoors spaces.
Technical Informations
- Performance
Application Limits
Technicial Specificationsa. Chemical Structure: Cement based grout mortar with high alumina cement content
b. Density: 2.0 ± 0.01 gr/cm³
c. Through Dry Time: 24 hours
d. Color: GrayMixing RatioThe product should be mixed with water, weighing equal to 17 – 19 % of the product. (4,25 – 4,75 liters of water for a 25 kg package)
ConsumptionRecommended consumption amount for application in roughly 1 mm thickness on 1 m² surface is 2.0 – 2.5 kg. The said value may vary, depending on the surface and ambient conditions.
PackagingMegaTamir Grout T105 is delivered in net 25 kg craft bags, which are stowed in 54 pcs. on a 80 cm x 100 cm palette (1350 kg).
Reference Standardsa. Certifications / Standards
• TS EN 1504 – 3
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 10.300.2073Quality Certificates
• TSE/ R4
• CE
Application Procedure
- Application Surfaces
Indoors and Outdoors Floors;
• Cement based trowel coating
• ConcreteSurface Preparation :
• The application surfaces should be dry, clean, sound and dust-free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
• In the cases of application on old concrete surfaces, the surface should be moisturized without causing any water accumulation.
• The mold to be used should be fixed firmly, be clean and be sealed for any potential leaks.
• Due care must be taken to ensure that there is no water accumulation on the surface in the case of any application. The water on the surface should be removed, where necessary, with compressed air.Application Methods :
• MegaTamir Grout T105 should be cast from one side of the mold, taking care not to cause the formation of air bubbles. (Mortar with air bubbles will preclude full contact bonding to the surface.)
• The mortar is recommended to be cast from a certain height in order to ensure the fluidity of the mortar in the case of base plate applications. (The mortar is recommended to the consumed within 15 minutes for maximum performance.)
• Application thickness must be min. 10 mm, max. 70 mm. The recommended maximum thickness for the bonding of precast concrete elements and fixed structural bearings is 60 mm. The mortar should be ensured to reach hardly reachable spots with the use of a metal or wooden rod.Application Recommendations :
• The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application.
• Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
• Any extra water should not be added to the mixture.
• The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
• Application thickness must be max. 50 mm per layer.
• The surface should be preserved from air currents and water contact during and after the application.
• The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
• Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
• The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
• The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: +90 444 4 595)Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.
- Application Surfaces
- Performance